EMISSION SOURCE TYPE: |
Miscellaneous - Process Heaters and Small Boilers
(generally
between 75,000 and 5
million Btu per hour) |
| CONTROL TYPE: |
BARCT/RACT |
KEY POLLUTANT: |
NOx |
| DESCRIPTION(S):
|
|
PLEASE REFER TO THE FOLLOWING FOR DETAILED RULES OR INFORMATION:
|
a) Applies to units between 75,000 and 2 million Btu, and limits NOx
emissions from units between 75,000 and 400,000 Btu to 55 parts per million;
and for units between 400,000 and 2 million Btu to 30 parts per million.
Applies to new, existing, and modified sources. |
|
Santa Barbara APCD
Rule 360 (pdf) |
| |
|
|
b) Limits NOx emissions from gaseous, liquid, or solid fossil fuel fired
boilers, steam generators, or process heaters with a total rated heat input
starting at 2 million Btu per hour up to 5 million Btu per hour used in any
industrial, institutional, or commercial operation to 30 parts per million
volume. Applies to new, existing, and modified sources. |
|
South Coast AQMD
Rule 1146.1 |
| |
|
|
c) Applies to any boiler, steam generator, or process heater with a rated
heat input capacity of 1 million Btu and less than 5 million Btu per hour.
Limits NOx emissions from boilers, generators, and heaters with an annual
rated heat input equal to or greater than 1.8 billion Btu to no more than 30
parts per million volume. Applies to new, existing and modified sources. |
|
Ventura County
APCD Rule 74.15.1 (pdf) |
| |
|
Please note that the document listed is
in Adobe Acrobat (pdf) format. To view or print this file you may
need to download the free
Acrobat